Database Lookup:
By Part Number
By Description
Total 8463 part numbers listed in this database. Shown in 265 pages by 32 items.
Pages: Prev , Next , 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126
Part Number
Product Category
Description
Image
Stock Qty
Weight (lbs.)
Price (US$)
Order Quantity
AME-1980-402-X-DP-X-R-10-R-1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-402-X-DP-X-R-10-R-1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 02 = 2 Independent Cams / Circuits / Switches. The micro-adjust cams maintain accuracy / repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand. The cams have a switch setting range of 4 through 356 Degrees X = No Shaft Extension Opposite the Gear Box DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 8 screw terminals per switch.Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial R= Right Angle Gear Reducer 10 = 10 to 1 Gear Ratio R1 = Right End Gear Reducer Shaft Location 1 [1/2017] [1/2018] [1/2018]
-
0
0.00
2,906.00
AME-1980-402-X-SPK-X-S-40-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-402-X-SPK-X-S-40-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure 2 = 2 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SPK = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch with Clamp Terminals X = No Timing Dial S = Straight Gear Reducer 40 = 40 to 1 Gear Ratio R = Right End Gear Reducer [1/2017] [1/2018] [1/2018]
-
0
0.00
3,048.00
AME-1980-402-X-SPR-X-R-7-L-1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-402-X-SPR-X-R-7-L1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Weatherproof / Water Tight 02 = 2 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No shaft extension opposite gearbox / no double shaft extension SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided R = Rubber Boots on plunger for additional water & dust protection R = Right Angle Gear Reducer 7 = 7 to 1 Gear Ratio L1 = Left End Gear Reducer Shaft Location 1
-
0
0.00
2,004.48
AME-1980-402-X-SP-X-R-28-R-1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-402-X-SP-X-R-28-R-1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Water Resistant for Outdoor Service 02 = 2 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No shaft extension opposite gearbox / no double shaft extension SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided R = Right Angle Gear Reducer 2 = 28 to 1 Gear Ratio R = Right End Gear Reducer Location 1 = Shaft Position 1
-
2
0.00
2,037.96
AME-1980-402-X-SP-X-R-40-R1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch 1980 Part 1980-402-X-SP-X-R-40-R-1 1980402XSPXR40R1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 04 = 4 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed. Switches can be wired to be a Normally Open or Normally Closed Circuit. 4 Screw Terminals per switch Part 1950-1-B-A-AO X = No Timing Dial is to be provided R = Right Angle Gear Reducer 40 = 40 to 1 Gear Ratio R = Right End Shaft Location 1 = Shaft Location Position 1 Ships in 6 Weeks, Peck MI Dated 06-2025
-
0
0.00
2,970.00
AME-1980-402-X-SP-X-R-40-R-1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch980 Part 1980-402-X-SP-X-R-40-R-1 1980402XSPXR40R1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 04 = 4 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed. Switches can be wired to be a Normally Open or Normally Closed Circuit. 4 Screw Terminals per switch Part 1950-1-B-A-AO X = No Timing Dial is to be provided R = Right Angle Gear Reducer 40 = 40 to 1 Gear Ratio R = Right End Shaft Location 1 = Shaft Location Position 1 Ships in 6 Weeks, Peck MI Dated 01-2024
-
0
0.00
2,800.00
AME-1980-402-X-SP-X-S-28-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-402-X-SP-X-S-28-L 1980= Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree And can be adjusted by use of a tool supplied and mounted inside the enclosure Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 4 = NEMA 4 Enclosure, Water Resistant, suitable for Outdoor Service 02 = 2 Independent Cams / Circuits / Switches X = No shaft extension opposite gearbox / no double shaft extension SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches Which can be wired for either a N.O. ot N.C. Circuit 4 Screw Terminals per switch Switch Part 1950-1-B-A-AO Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided S = Straight Drive Gear Reducer 28 = 28 to 1 Gear Ratio L = Left End Gear Reducer Location Ships in 3 Weeks Dated 1-19
-
0
0.00
2,408.40
AME-1980-402-X-SP-X-S-2-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-402-X-SP-X-S-28-R aka 1980402XSPXS2R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell Switch Settings 4 to 356 Degrees 4 = NEMA 4 Enclosure, Water Resistant suitable for Outdoor Service 02 = 2 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree And can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No shaft extension opposite gearbox / no double shaft extension SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches Which can be wired for either a N.O. or N.C. Circuit 4 Screw Terminals per switch, Switch Part 1950-1-B-A-AO Gemco MFG Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided S = Straight Drive Gear Reducer 2 = 2 to 1 Gear Ratio R = Right End Gear Reducer Location Ships in 3 to 4 Weeks Dated 1-19
-
0
0.00
3,016.00
AME-1980-402-Y-SP-X-S-40-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch 1980-402-Y-SP-X-S-40-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure 02 = 2 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand Y = Shaft Extension Opposite Gearbox SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided S = Straight Drive Gear Reducer 40 = 40 to 1 Gear Ratio R = Right End Gear Reducer Location [1/2017] [1/2018] [1/2018]
-
0
0.00
3,103.00
AME-1980-403-R-SP-TD1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-403-R-SP-TD1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 03 = 3 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand R = Right Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 TD1 = Timing Dial Labeled for C.W. Rotation 3 Year Limited Warranty (20BS) [1/2017] [1/2018] [1/2018]
-
0
0.00
2,046.00
AME-1980-403-X-DP-TD1-S7-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-403-X-DP-TD1-S7-L Series 1980 4 = NEMA 4 Enclosure 3 = 3 Cams / Circuits / Switches X = No shaft extension opposite gear box DP = DPDT Switches / Double Pole Double Throw TD1 = Timing Dial Labeled for Clock wise Rotation S = Straight Drive Gear Reducer 7 = 7 to 1 Gear Ratio L = Left End Shaft Location
-
0
0.00
2,584.44
AME-1980-403-X-DP-X-M4-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-403-X-DP-X-M4-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Water Resistant / Weatherproof 03 = 3 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No Shaft Extension Opposite the Gear Box DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 8 screw terminals per switch X = No Timing Dial M = Straight Drive Gear Multiplier 4 = 1 to 4 Gear Ratio Multiplier R = Right End Shaft Location
-
0
0.00
2,374.92
AME-1980-403-X-DP-X-S-200-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-403-X-DP-X-S-200-L Series 1980 4 = NEMA 4 Enclosure 3 = 3 Cams / Circuits / Switches X = No shaft extension opposite gear box DP = DPDT Switches / Double Pole Double Throw X = No Timing Dial or Dial Window is provided S = Straight Drive Gear Reducer 200 = 200 to 1 Gear Ratio L = Left End Shaft Location 26 LBS Gross [1/2017] [1/2018] [1/2018]
-
0
0.00
3,356.00
AME-1980-403-X-SP-X-S-2.5-R
Gemco Parts
Ametek Gemco 1980 Cam Limit Switch Part 1980-403-X-SP-X-S-2.5-R
-
0
0.00
1,918.08
AME-1980-403-X-SP-X-S200-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-403-X-SP-X-S-200-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure / Watertight 03 = 3 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree Can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No shaft extension opposite gear box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches Which can be wired for either a N.O. or N.C. Circuits 4 Screw Terminals per switch X = No Timing Dial or Dial Window is provided S = Straight Drive Gear Reducer 200 = 200 to 1 Gear Ratio R = Right End Shaft Location Dated 1/18 Ships in 3 weeks, OH 44023 26 LBS
-
0
0.00
3,200.00
AME-1980-404 X-SP-R-X-S-60-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-X-SP-R-X-S-60-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 04 = 4 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No shaft extension opposite gearbox / no double shaft extension SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 R = R = Rubber boot on Switch Plunger for additional moisture protection X = No Timing Dial or Dial Window is to be provided S= Straight Drive Gear Reducer. Shaft parallel to main shaft 60 = 60 to 1 Gear Ratio R = Right End Gear Reducer Location (26LBS)
-
0
0.00
3,456.00
AME-1980-404-D-SP-R-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-D-SP-R-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell04 = NEMA 4 Rated Enclosure 04 = 4 Cams / Circuits / Switches D = Double / 2 Shaft Extensions from enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch R = Rubber Boot on Switch Plunger for addition moisture & contaminant protection X = No Timing Dial or Dial Window is provided 3 Year Limited Warranty (19LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
2,092.00
AME-1980-404-D-SP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch 1980 Part 1980-404-D-SP-X 1980404DSPX Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Water Resistant 4 = 4 Independent Circuits - Switches - Cams D = Double Shaft Extension, Shaft Extension from both ends of the enclosure SP = S.P.D.T. Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches can be wired for N.O. or N.C Circuit 4 Screw Terminals per switch X = No Timing Dial or Dial Window is provided 3 Year Limited Warranty, Peck MI Ships in 6 Weeks, Peck MI Dated 06-2022 Price increase 01-01-2022 about 5% (20LBS)
-
0
0.00
2,028.00
AME-1980-404-L-DP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-L-DP-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 4 = 4 Independent Cams / Circuits / Switches L = Left Hand Shaft Extension from enclosure DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches can be wired for a Normally Open or Normally Closed Circuit 8 screw terminals per switch X = No Timing Dial or Dial Window is provided 3 Year Warranty (18LBS) 1/17
-
0
0.00
2,149.00
AME-1980-404-L-SP-TD1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch 1980 Part 1980-404-L-SP-TD1 1980404LSPTD1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 4 = 4 Independent Cams - Circuits - Switches L = Left Hand Shaft Extension from enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed. Switches can be wired for a Normally Open or Normally Closed Circuit. 4 screw terminals per switch TD! = Timing Dial CW Rotation 3 Year Limited Warranty Ships in 2 to 3 Weeks, Peck MI Dated 02-2025 (18LBS)
-
0
0.00
2,372.00
AME-1980-404-L-SP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-L-SP-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 4 = 4 Independent Cams / Circuits / Switches L = Left Hand Shaft Extension from enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed. Switches can be wired to be a Normally Open or Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial or Dial Window is provided 3 Year Warranty (18LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
1,941.00
AME-1980-404-R-DP-TD1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-R-DP-TD1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Watertight 04 = 4 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand R = Right Hand Shaft Extension from Enclosure DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 8 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 TD1 = Timing Dial Labeled for Clockwise Rotation 3 Year Limited Warranty (12LBS)
-
0
0.00
1,732.32
AME-1980-404-R-DP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-R-DP-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 4 = 4 Independent Cams / Circuits / Switches R = Right Hand Shaft Extension from enclosure DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed. Switches can be wired to be a Normally Open or Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial or Dial Window is provided 3 Year Warranty (18LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
2,149.00
AME-1980-404-R-SP-R-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-R-SP-R-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 04 = 4 Independent Cams / Circuits / Switches R = Right Hand Shaft Extension from enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches Which can be wired for N.O or N.C. Circuits. 4 screw terminals per switch R = Rubber Boot on Switch Plunger for addition moisture & dust protection X = No other options [Amazon] Dated 1/17 (20LBS) H 8" L 18" W 12" [1/2018] [1/2018]
1
0.00
2,005.00
AME-1980-404-R-SP-TD1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-R-SP-TDI Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Watertight 04 = 4 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand R = Right Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 TD1 = Timing Dial labeled for Clockwise Rotation 3 Year Limited Warranty [1/2017] [1/2018] [1/2018]
-
0
0.00
2,238.00
AME-1980-404-R-SP-TD2
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch 1980 Part 1980-404-R-SP-TD2 1980404RSPTD2 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 4 = 4 Independent Cams - Circuits - Switches R = Right Hand Shaft Extension from enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed. Switches can be wired for a Normally Open or Normally Closed Circuit. 4 screw terminals per switch TD2 = Timing Dial CCW Rotation 3 Year Limited Warranty Ships in 2 to 3 Weeks, Peck MI (18LBS)
-
0
0.00
2,372.00
AME-1980-404-R-SP-TW2
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-R-SP-TW2 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Watertight 04 = 4 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand R = Right Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 TW2 = Timing Dial & Timing Dial Window, Labeled for CCW Rotation 3 Year Limited Warranty [1/2017] [1/2018] [1/2018]
-
0
0.00
2,314.00
AME-1980-404-R-SP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-R-SP-X aka 1980404RSPX Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell Switch Settings 4 to 356 Degrees 4 = NEMA 4 Enclosure, Water resistant suitable for outdoor service 04 = 4 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree Adjusted by use of a tool supplied and mounted inside the enclosure or by hand R = Right Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action Which can be wired for either a N.O. or N.C. Circuits 4 screw terminals per switch - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided 3 Year Limited Warranty Ships from Stock to 2 Weeks Dated 1-19 (15LBS) H 8" L 18" W 12" Box
-
0
0.00
1,941.00
AME-1980-404-X-DP-R-X-R-1-R-3
Gemco Parts
Ametek Gemco 1980 Rotating Cam Limit Switch Model 1980-404-X-DP-R-X-R-1-R3 aka 1980404XDPRXR1R3 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Water Resistant suitable for outdoor service 04 = 4 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches can be wired for N.O. or N.C. Circuits 8 screw terminals per switch R = Rubber Boots on the switch plungers For Additional Dust & Moisture protection X = No Timing Dial R = Right Angle Gear Reducer 1 = 1 to 1 Gear Ratio R = Right End Shaft Location 3 = Shaft Location Position 3 Mfg in Peck MI 3 Year Limited Warranty @ Peck MI Ships in 3 weeks, OH 44023 Dated 1-19
-
0
0.00
3,450.00
AME-1980-404-X-DP-R-X-S1-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-X-DP-R-X-S1-L Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 04 = 4 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree Can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No shaft extension opposite gearbox DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches Which can be wired for either a N.O. or N.C. Circuit 8 screw terminals per switch UL Listed Assembly File E56660 Switch Settings 4 to 356 Degrees UL Listed Assembly File E56660 R = Rubber Boots on the Snap Switch Plunger for additional dust & moisture protection X = No Timing Dial or Dial Window is to be provided S = Straight Drive Gear Reducer 1 = 1 to 1 Gear Ratio L = Left End Gear Reducer (24LBS)
-
0
0.00
2,796.12
AME-1980-404-X-DP-TD2-S-2-R
Gemco Parts
Ametek Gemco 1980 Series Cam Limit Switch Part 1980-404-X-DP-TD2-S-2-R Ships in 4 to 4 weeks Dated 1/18
-
0
0.00
3,026.16
AME-1980-404-X-DP-X-M4-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-404-X-DP-X-M4-L Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Water Tight / Weatherproof 04 = 4 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No Shaft Extension Opposite the Gear Box DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 8 screw terminals per switch X = No Timing Dial M = Straight Drive Gear Multiplier 4 = 1 to 4 Gear Ratio Multiplier L = Left End Shaft Location
-
0
0.00
2,548.80