Database Lookup:
By Part Number
By Description
Total 8463 part numbers listed in this database. Shown in 265 pages by 32 items.
Pages: Prev , Next , 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130
Part Number
Product Category
Description
Image
Stock Qty
Weight (lbs.)
Price (US$)
Order Quantity
AME-1980-408-X-DP-X-S-6-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-408-X-DP-X-S-6-L Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure 08 = 8 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 8 screw terminals per switch X = No Timing Dial S= Straight Drive Gear Reducer 6 = 6 to 1 Gear Ratio L = Left End Gear Reducer (36LBS)
-
0
0.00
3,476.52
AME-1980-408-X-DP-X-S-8-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-408-X-DP-X-S-8-L Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure 08 = 8 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box DP = DPDT Switches / Double Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 8 screw terminals per switch X = No Timing Dial S= Straight Drive Gear Reducer 8 = 8 to 1 Gear Ratio L = Left End Gear Reducer (36LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
4,910.00
AME-1980-408-X-SP-X-R-30-R1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch 1980 Part 1980-408-X-SP-X-R-30-R1 1980408XSPXR30R1 Series 1980 Cam Box featuring Cams with Adjustable Timing & Dwell The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand Switch Settings 4 to 356 Degrees 4 = NEMA 4 Rated Enclosure 08 = 8 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite Gear Box SP = SPDT Switches - Single Pole Double Throw, Snap Action, U.L. Listed Switches File E56660 Which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial R = Right Angle Gear Reducer 30 = 30 to 1 Gear Ratio R1 = Right End Gear Reducer, Position 1 Ships in 4 to 6 Weeks, Peck MI Dated 12-2024
-
0
0.00
4,280.00
AME-1980-408-X-SP-X-S30-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-408-X-SP-X-S-30-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Watertight 08 = 8 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial S = Straight Drive Gear Reducer 30 = 30 to 1 Gear Ratio R = Right End Shaft / Gearbox Location [1/2017] [1/2018] [1/2018]
-
0
0.00
4,494.00
AME-1980-408-X-SP-X-S4-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-408-X-SP-X-S-4-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Watertight 08 = 8 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial S = Straight Drive Gear Reducer 4 = 4 to 1 Gear Ratio R = Right End Shaft / Gearbox Location [1/2017] [1/2018] [1/2018]
-
0
0.00
4,494.00
AME-1980-408-Y-SP-X-M-4-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-408-Y-SP-X-M-4-L Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 08 = 8 Independent Cams / Circuits / Switches Y = Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial M= Multiplier Drive 4 = 1 to 4 Multiplier Ratio L = Left End Shaft Location (36LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
4,581.00
AME-1980-409-Y-SP-X-S-8-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-409-Y-SP-X-S-8-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure 09 = 9 Independent Cams / Circuits / Switches Y = Shaft Extension Opposite the Gear Box / Dual Output Shafts SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial S= Straight Drive Gear Reducer 8 = 8 to 1 Gear Ratio R = Right End Gear Reducer (41LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
5,306.00
AME-1980-410-R-SP-R-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-410-R-SP-R-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 10 = 10 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand R = Right Hand Shaft Extension SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 R = Rubber Boot / Seal on the Switch Plunger for additional moisture & dust protection X = No Timing Dial or Dial Window is to be provided 3 Year Limited Warranty [1/2017] [1/2018] [1/2018]
-
0
0.00
4,199.00
AME-1980410RSPX
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch 1980 Part 1980-410-R-SP-X 1980410RSPX 1980 = 1980 Cam Box featuring Cams with Adjustable Timing & Dwell The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree Can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand Switch Settings 4 to 356 Degrees 4 = NEMA 4 Rated Enclosure, Water Resistant suitable for outdoor service 10 = 10 Independent Cams / Circuits / Switches R = Right Hand Shaft Extension SP = S.P.D.T. Switches, UL Listed Assembly File E56660 Which can be wired for a N.O. or N.C. Circuit 4 Screw Terminals per switch X = No Timing Dial or Dial Window is to be provided 3 Year Limited Warranty Ships in 3 Weeks, Peck MI Dated 01-2023
-
0
0.00
3,810.00
AME-1980-410-X-SP-TD2-S-35-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-410-X-SP-TD2-S-35-L Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 10 = 10 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch TD2 = Timing Dial Labeled for Counter Clock Wise Rotation S= Straight Drive Gear Reducer 35= 35 to 1 Gear Ratio L = Left End Shaft Location (24LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
5,787.00
AME-1980-410-Y-SP-X-S-6-L
Gemco Parts
AME-1980-410-Y-SP-X-S-6-L
-
0
0.00
6,576.25
AME-1980-410-Y-SP-X-S-6-R
Gemco Parts
Ametek Gemco 1980 Cam Limit Switch Part 1980-410-Y-SP-X-S-6-R Dated 1/18
-
0
0.00
4,326.48
AME-1980-411-D-SP-TD2
Gemco Parts
Ametek Gemco 1980 Cam Limit Switch Part 1980-411-D-SP-TD2 1980411DSPTD2 Ships in 3 Weeks, Peck MI Dated 01-2024
-
0
0.00
4,735.00
AME-1980-411-L-SP-TD1
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Part 1980-411-L-SP-TD1 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 11= 11 Independent Cams / Circuits / Switches L = Left Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches can be wired to be a N.O. or N.C. Circuit 4 Screw Terminals per switch TD1 = Timing Dial Labeled for C.W. Rotation Ships in 2 Weeks Dated 1-19
-
0
0.00
4,648.00
AME-1980-411-L-SP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-411-L-SP-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 1 Rated Enclosure 11 = 4 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand L = Left Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided 3 Year Limited Warranty [1/2017] [1/2018] [1/2018]
-
0
0.00
4,351.00
AME-1980-411-R-SP-TD2
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-411-R-SP-TD2 Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 11= 11 Independent Cams / Circuits / Switches R = Right Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed. Switches can be wired to be a Normally Open or Normally Closed Circuit. 4 screw terminals per switch TD2 = Timing Dial Labeled for C.C.W. Counter Clock Wise Rotation but without timing dial window on the enclosure 3 Year Warranty (36LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
4,648.00
AME-1980-411-X-SP-X-M-4-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-411-X-SP-X-M-4-R Series 1980 4 = NEMA 4 Enclosure 11= 11 Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches, Single Pole Double Throw X = No Timing Dial M = Multiplier Drive 4 = 4 to 1 Gear Multiplier R = Right End Shaft Location (43LBS) [1/2017] [1/2018] [1/2018]
-
0
0.00
5,802.00
AME-1980-411-X-SP-X-S-20-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-411-X-SP-X-S-20-L 1980411XSPXS20L Series 1980 4 = NEMA 4 Enclosure 11 = 11 Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches, Single Pole Double Throw X = No Timing Dial S = Straight Drive Gear Reducer 20 = 20 to 1 Gear Ratio L = Left End Gear Reducer / Shaft Location Dated 01-2020 Ships in 3 to 4 Weeks (41LBS) H 10" L 26" W 12" Box
-
0
0.00
5,474.00
AME-1980-411-X-SP-X-S-4-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-411-X-SP-X-S-4-R Series 1980 4 = NEMA 4 Enclosure 11= 11 Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches, Single Pole Double Throw X = No Timing Dial S = Straight Drive Gear Reducer 4 = 4 to 1 Gear Ratio R = Right End Shaft Location Dated 1/17 (56LBS) H 10" L 26" W 12" Box [1/2018] [1/2018]
-
0
0.00
5,802.00
AME-1980-412-D-SP-TD3
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-412-D-SP-TD3
-
0
0.00
3,535.92
AME-1980-412-D-SP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-412-D-SP-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 12 = 12 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree Can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand D = Dual Shaft Extensions from the Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches Which can be wired for either a N.C. or N.O. Circuit 4 screw terminals per switch Switch Settings 4 to 356 Degrees Gemco Manufactured Precision Snap Switches UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided 3 Year Limited Warranty Ships in 2 weeks, OH 44023 Dated 1/18
-
0
0.00
4,712.00
AME-1980-412-L-SP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-412-L-SP-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Watertight 12 = 12 Independent Circuits / Switches / Cams The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand L = Left Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No other options 3 Year Limited Warranty [1/2017] [1/2018] [1/2018]
-
0
0.00
4,625.00
AME-1980-412-R-SP-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-412-R-SP-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Watertight 12 = 12 Independent Circuits / Switches / Cams The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand R = Right Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No other options 3 Year Limited Warranty [1/2017] [1/2018] [1/2018]
-
0
0.00
4,625.00
AME-1980-412-X-SP-X-S-100-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-412-X-SP-X-S-100-R Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure 12= 12 Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed. Switches can be wired to be a Normally Open or Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial S = Straight Drive Gear Reducer 100 = 100 to 1 Gear Ratio R = Right End Shaft Location 41 LBS [1/2017] [1/2018] [1/2018]
-
0
0.00
6,076.00
AME-1980-412-X-SP-X-S10-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-412-X-SP-X-S-10-L Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Enclosure, Watertight 12 = 12 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial S = Straight Drive Gear Reducer 10 = 10 to 1 Gear Ratio L = Left End Shaft Location [1/2017] [1/2018] [1/2018]
-
0
0.00
6,076.00
AME-1980-412-X-SP-X-S-48-L
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-412-X-SP-X-S-48-L Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Rated Watertight Enclosure 12 = 12 Independent Cams / Circuits / Switches X = No Shaft Extension Opposite the Gear Box SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch X = No Timing Dial S= Straight Drive Gear Reducer 48 = 48 to 1 Gear Ratio L = Left End Shaft Location [1/2017] [1/2018] [1/2018]
-
0
0.00
6,076.00
AME-1980-412-Y-SP-X-M-6-R
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-412-Y-SP-X-M-6-R Series 1980 4 = NEMA 4 Enclosure 12 = 12 Cams / Circuits / Switches Y = Shaft Extension oposite gearbox. (double) SP = SPDT Switches. Single Pole Double Throw X = No Timing Dial M = Mutiplier Drive 6 = 1 to 6 Gear Multiplier Ratio R = Gear Multiplier, Right End Loc [1/2017] [1/2018] [1/2018]
-
0
0.00
6,163.00
AME-1980-4146
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell NEMA 1 Rated Enclosure 5 Independent Cams / Circuits / Switches With the "Add a CAM Feature" and a 45 Degree Special Cam The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand Left Hand Shaft Extension from Enclosure SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 Provisions for a Resolver though it is NOT included 3 Year Limited Warranty (18LBS)
-
0
0.00
1,809.00
AME-1980-4160
Gemco Parts
Ametek Gemco Cam Box like 1980R-406-X-DP-X-R-3-L with 304 Stainless Steel Option. NEMA 4X, 6 Circuits, 3 to 1 Ratio, Includes Resolver EC70289 # SD0308910. Enclosure size is to be the same as original units. Bascular Span Drawbridge Long Island NY. 1980-4160 RAGR/SS EN
-
0
0.00
4,600.79
AME-1980-4161
Gemco Parts
Ametek Gemco Cam Box like1980R-406-X-DP-X-R-3-R with 304 Stainless Steel Option. NEMA 4X, 6 Circuits, 3 to 1 Ratio, Includes Resolver EC70289 # SD0308910. Enclosure size is to be the same as original units. Bascular Span Drawbridge Long Island NY. 1980-4161 RAGR/SS EN
-
0
0.00
4,600.79
AME-1980-4163
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell NEMA 1 Enclosure, Sheet Metal Cover 6 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand Right Hand Shaft Extension from Enclosure 1 Special Precut 30 Degree Cam Dwell in Circuit 6. This cam has a permanent 30 degree dwell set for plus 15 degrees and minus 15 degrees dwell from the hone position SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 X = No Timing Dial or Dial Window is to be provided 3 Year Limited Warranty (14LBS) 1/12
-
0
0.00
1,205.28
AME-1980-416-R-SP-R-X
Gemco Parts
Ametek Gemco Rotating Cam Limit Switch Model 1980-416-R-SP-R-X Series 1980 Cam Box featuring cams with Adjustable Timing & Dwell 4 = NEMA 4 Enclosure, Watertight 16 = 16 Independent Cams / Circuits / Switches The micro-adjust cams maintain an accuracy and repeatability of 1/4 degree and can be adjusted by use of a tool supplied and mounted inside the enclosure or by hand R = Right Hand Shaft Extension from Enclosure SP = SPDT Switches / Single Pole Double Throw, Snap Action, U.L. Listed Switches which can be wired for either a Normally Open or a Normally Closed Circuit. 4 screw terminals per switch Switch Settings 4 to 356 Degrees - Gemco Manufactured Precision Snap Switches - UL Listed Assembly File E56660 R = Rubber Boot / Seal on the Switch Plunger for additional dust & moisture protection X = No Timing Dial or Dial Window is to be provided 3 Year Limited Warranty [1/2017] [1/2018] [1/2018]
-
0
0.00
5,979.00