Database Lookup:        
          
            By Part Number
             By Description
               
           
         
       
     
    
      
        Total 48169 part numbers listed in this database.  Shown in 1506 pages by 32 items.     
   
  Pages:    Prev ,   Next ,   98   99   100   101   102   103   104   105   106   107   108   109   110   111   112   113   114   115   116   117   118  
  
    Part Number 
    Product Category 
    Description 
    Image 
    Stock Qty 
    Weight (lbs.) 
    Price (US$) 
    Order Quantity 
   
  AME-1500-J-L3-S2-N12-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S2-N12-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S2 - Secondary Coil Voltage: 24 Volts A.C., Typical Liquids: (Metallic circuits);  Enclosure Type:    N12 - NEMA 12, Oil Tight;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  332.00 
  
 
 
  AME-1500-J-L3-S2-N1-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S2-N1-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S2 - Secondary Coil Voltage: 24 Volts A.C., Typical Liquids: (Metallic circuits);  Enclosure Type:    N1 - NEMA 1, General Purpose;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  264.00 
  
 
 
  AME-1500-J-L3-S2-N4X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S2-N4X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S2 - Secondary Coil Voltage: 24 Volts A.C., Typical Liquids: (Metallic circuits);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  397.00 
  
 
 
  AME-1500-J-L3-S2-N4X-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S2-N4X-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S2 - Secondary Coil Voltage: 24 Volts A.C., Typical Liquids: (Metallic circuits);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  588.00 
  
 
 
  AME-1500-J-L3-S2-N7-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S2-N7-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S2 - Secondary Coil Voltage: 24 Volts A.C., Typical Liquids: (Metallic circuits);  Enclosure Type:    N7 - NEMA 7, Classified Location;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  1,511.00 
  
 
 
  AME-1500-J-L3-S2-OC-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S2-OC-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S2 - Secondary Coil Voltage: 24 Volts A.C., Typical Liquids: (Metallic circuits);  Enclosure Type:    OC - Open Chassis;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  225.00 
  
 
 
  AME-1500-J-L3-S3-N12-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S3-N12-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S3 - Secondary Coil Voltage: 40 Volts A.C., Typical Liquids: (Acid or caustic solutions: Milk; Brine and salt solutions; Plating solutions; Buttermilk; Soups);  Enclosure Type:    N12 - NEMA 12, Oil Tight;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  332.00 
  
 
 
  AME-1500-J-L3-S3-N1-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S3-N1-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S3 - Secondary Coil Voltage: 40 Volts A.C., Typical Liquids: (Acid or caustic solutions: Milk; Brine and salt solutions; Plating solutions; Buttermilk; Soups);  Enclosure Type:    N1 - NEMA 1, General Purpose;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  264.00 
  
 
 
  AME-1500-J-L3-S3-N4X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S3-N4X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S3 - Secondary Coil Voltage: 40 Volts A.C., Typical Liquids: (Acid or caustic solutions: Milk; Brine and salt solutions; Plating solutions; Buttermilk; Soups);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  397.00 
  
 
 
  AME-1500-J-L3-S3-N4X-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S3-N4X-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S3 - Secondary Coil Voltage: 40 Volts A.C., Typical Liquids: (Acid or caustic solutions: Milk; Brine and salt solutions; Plating solutions; Buttermilk; Soups);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  588.00 
  
 
 
  AME-1500-J-L3-S3-N7-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S3-N7-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S3 - Secondary Coil Voltage: 40 Volts A.C., Typical Liquids: (Acid or caustic solutions: Milk; Brine and salt solutions; Plating solutions; Buttermilk; Soups);  Enclosure Type:    N7 - NEMA 7, Classified Location;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  1,511.00 
  
 
 
  AME-1500-J-L3-S3-OC-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S3-OC-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S3 - Secondary Coil Voltage: 40 Volts A.C., Typical Liquids: (Acid or caustic solutions: Milk; Brine and salt solutions; Plating solutions; Buttermilk; Soups);  Enclosure Type:    OC - Open Chassis;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  225.00 
  
 
 
  AME-1500-J-L3-S4-N12-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S4-N12-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S4 - Secondary Coil Voltage: 90 Volts A.C., Typical Liquids: (Weak acid or caustic solutions: Beer; Baby foods; Fruit juices);  Enclosure Type:    N12 - NEMA 12, Oil Tight;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  332.00 
  
 
 
  AME-1500-J-L3-S4-N1-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S4-N1-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S4 - Secondary Coil Voltage: 90 Volts A.C., Typical Liquids: (Weak acid or caustic solutions: Beer; Baby foods; Fruit juices);  Enclosure Type:    N1 - NEMA 1, General Purpose;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  264.00 
  
 
 
  AME-1500-J-L3-S4-N4X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S4-N4X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S4 - Secondary Coil Voltage: 90 Volts A.C., Typical Liquids: (Weak acid or caustic solutions: Beer; Baby foods; Fruit juices);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  397.00 
  
 
 
  AME-1500-J-L3-S4-N4X-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S4-N4X-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S4 - Secondary Coil Voltage: 90 Volts A.C., Typical Liquids: (Weak acid or caustic solutions: Beer; Baby foods; Fruit juices);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  588.00 
  
 
 
  AME-1500-J-L3-S4-N7-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S4-N7-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S4 - Secondary Coil Voltage: 90 Volts A.C., Typical Liquids: (Weak acid or caustic solutions: Beer; Baby foods; Fruit juices);  Enclosure Type:    N7 - NEMA 7, Classified Location;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  1,511.00 
  
 
 
  AME-1500-J-L3-S4-OC-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S4-OC-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S4 - Secondary Coil Voltage: 90 Volts A.C., Typical Liquids: (Weak acid or caustic solutions: Beer; Baby foods; Fruit juices);  Enclosure Type:    OC - Open Chassis;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  225.00 
  
 
 
  AME-1500-J-L3-S7-N12-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S7-N12-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S7 - Secondary Coil Voltage: 220 Volts A.C., Typical Liquids: (Sewage; Most water-except very soft; Pottery slip; Water soluble oil solutions; Starch solutions);  Enclosure Type:    N12 - NEMA 12, Oil Tight;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  332.00 
  
 
 
  AME-1500-J-L3-S7-N1-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S7-N1-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S7 - Secondary Coil Voltage: 220 Volts A.C., Typical Liquids: (Sewage; Most water-except very soft; Pottery slip; Water soluble oil solutions; Starch solutions);  Enclosure Type:    N1 - NEMA 1, General Purpose;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  264.00 
  
 
 
  AME-1500-J-L3-S7-N4X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S7-N4X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S7 - Secondary Coil Voltage: 220 Volts A.C., Typical Liquids: (Sewage; Most water-except very soft; Pottery slip; Water soluble oil solutions; Starch solutions);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  397.00 
  
 
 
  AME-1500-J-L3-S7-N4X-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S7-N4X-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S7 - Secondary Coil Voltage: 220 Volts A.C., Typical Liquids: (Sewage; Most water-except very soft; Pottery slip; Water soluble oil solutions; Starch solutions);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  588.00 
  
 
 
  AME-1500-J-L3-S7-N7-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S7-N7-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S7 - Secondary Coil Voltage: 220 Volts A.C., Typical Liquids: (Sewage; Most water-except very soft; Pottery slip; Water soluble oil solutions; Starch solutions);  Enclosure Type:    N7 - NEMA 7, Classified Location;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  1,511.00 
  
 
 
  AME-1500-J-L3-S7-OC-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S7-OC-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S7 - Secondary Coil Voltage: 220 Volts A.C., Typical Liquids: (Sewage; Most water-except very soft; Pottery slip; Water soluble oil solutions; Starch solutions);  Enclosure Type:    OC - Open Chassis;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  225.00 
  
 
 
  AME-1500-J-L3-S8-N12-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S8-N12-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S8 - Secondary Coil Voltage: 360 Volts A.C., Typical Liquids: (Very soft water; Sugar syrup);  Enclosure Type:    N12 - NEMA 12, Oil Tight;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  332.00 
  
 
 
  AME-1500-J-L3-S8-N1-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S8-N1-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S8 - Secondary Coil Voltage: 360 Volts A.C., Typical Liquids: (Very soft water; Sugar syrup);  Enclosure Type:    N1 - NEMA 1, General Purpose;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  264.00 
  
 
 
  AME-1500-J-L3-S8-N4X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S8-N4X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S8 - Secondary Coil Voltage: 360 Volts A.C., Typical Liquids: (Very soft water; Sugar syrup);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  397.00 
  
 
 
  AME-1500-J-L3-S8-N4X-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S8-N4X-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S8 - Secondary Coil Voltage: 360 Volts A.C., Typical Liquids: (Very soft water; Sugar syrup);  Enclosure Type:    N4X - NEMA 4X, Corrosion Resistant;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  588.00 
  
 
 
  AME-1500-J-L3-S8-N7-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S8-N7-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S8 - Secondary Coil Voltage: 360 Volts A.C., Typical Liquids: (Very soft water; Sugar syrup);  Enclosure Type:    N7 - NEMA 7, Classified Location;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  1,511.00 
  
 
 
  AME-1500-J-L3-S8-OC-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S8-OC-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S8 - Secondary Coil Voltage: 360 Volts A.C., Typical Liquids: (Very soft water; Sugar syrup);  Enclosure Type:    OC - Open Chassis;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  225.00 
  
 
 
  AME-1500-J-L3-S9-N12-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S9-N12-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S9 - Secondary Coil Voltage: 480 Volts A.C., Typical Liquids: (Steam condensate; Strong alcohol solutions);  Enclosure Type:    N12 - NEMA 12, Oil Tight;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  332.00 
  
 
 
  AME-1500-J-L3-S9-N1-X 
  Ametek Parts 
  Ametek Gemco Induction Control Relays, Series 1500, P/N: AME-1500-J-L3-S9-N1-X  Contact Arrangements:    J - 0 NO, 3 NC;  All contacts rated at:    25 Amp Resistive at 120, 240, or 480 VAC; 1 HP Single Phase at 120 or 240 VAC; Heavy Duty Pilot 120 to 600 VAC; 2 Amp Resistive at 120 VDC; 10 Amp Resistive at 48 VDC;  Line Voltage:    L3 - 440-480 Volts, 50/60 HZ;  Secondary Coil Voltage:    S9 - Secondary Coil Voltage: 480 Volts A.C., Typical Liquids: (Steam condensate; Strong alcohol solutions);  Enclosure Type:    N1 - NEMA 1, General Purpose;  Additional Options:    X - None;  (1LBS) H 4"  L 6"  W 4"  [Amazon]  [1/2017] 
   
  0 
  0.00 
  264.00