  GEMCO Type H & HM Installation, Dimensions
     and Service Manual:

  Type H Brake System
  Type HM Brake System
  General
  Brake Dimensions
  Air-Over-Hydraulic (Type A/H)
     Brake System
  Air-Over-Hydraulic Parking
     (Type A/HM) Brake System
  Type A/H and A/HM General
     Information
  General Troubleshooting
 
 
 
 
 
 
 
  NOTE: Installation and service
  information for control cylinder,
  fluid reservoir bleeder, and
  pushbutton illustrated under
  Type H brake systems also
  apply to Type HM systems.
     INSTALLATION
  6 x 3 and 8 x 3 Type HM
     Brakes
  10 x 4, 14 x 6 and 18 x 8
     Type HM Brake
  Type HM Parking Brake
     Control Unit (Incl. J45767
     switch & light)
  Wiring Diagram Type HM
     Parking Control Unit
  Piping Diagram One Brake,
     6 x 3 and 8 x 3 Type HM
  Piping Diagram Two Brakes,
     6 x 3 and 8 x 3 Type HM
  Piping Diagram One Brake,
     10 x 4, 14 x 6 and 18 x 8
     Type HM
     SERVICE
  6 x 3 and 8 x 3 Type HM
  10 x 4, 14 x 6 and 18 x 8
     Type HM Brake
  Servicing 10", 14" and 18"
     Type HM Park Release
     Cylinders
 
And   Or     All Site   Selected Product
Order Details
Items 0
Total $0.00
 
 
Logon Status
Not logged on

Download
 GEMCO Type H & HM Installation, Dimensions and
 Service Manual:
   Microsoft Word® 97 format (3.6 MB)
   Adobe Acrobat® format (3.3 MB)
Get Viewer
Get Reader
INSTALLATION INSTRUCTIONS
Type HM Parking Control Unit Wiring Diagram
 
FRB Fluid Reservoir/Bleeder (On Crane)
TERM Transient Suppressor and Rectifier Module
must be connected in circuit at all times. The module will protect the solenoid check valve coils by suppressing voltage surges that can occur in DC power supplies. The module operates as a full wave rectifier when the power supply is 115VAC.
SCV Solenoid Check Valve.
Subpart of J107206 HM Control Unit (*)
PBL Parking Brake Light.
Subpart of J45767 switch and light in cab. Connect as shown for 230V power supply. Use 115V terminal if 115V power supply used.
MPR Motor Pilot Relay.
Supplied by customer. Connect contacts to prevent drive motor operation until hydraulic pressure switch is closed.

 
(*) NOTE: HM control unit is pre-wired for 230V DC operation. If the power supply is 115VAC, the solenoid coil must be re-wired as shown above.
BPB Bleeder Pushbutton. J10008 in cab.
PBS Parking Brake Switch. Sub part of J45767 Switch and Light Assembly. Connect "Normally Closed" terminals so that the TSRM and solenoid check valve are energized to keep the parking brake off when the selector switch is in the "OFF" position and the parking brake is on when the switch is in the "ON" position. If a "2 station" system is used, use two switch and light assemblies and connect the N.C. and N.O. contacts as a SPDT switch. Block out "OFF" and "ON" legends.
PS Pressure Switch. Subpart of J107206 HM Control Unit. B and C contacts are preconnected for Normally Open switch operation. Switch must be adjusted so that contacts close at 400 psi and open at 320 psi hydraulic pressure.