     INSTALLATION
  Type A/H-ARC-Panel (small
     unit) J070970 - J070973
  Type A/H-ERC Panel (large
     unit) J070980 - J070987
  Type A/H-HRC Panel
     J071020 - J0701027
  Type A/H-ARC Panel
     J089660 - J089667
 
And   Or     All Site   Selected Product
Order Details
Items 0
Total $0.00
 
 
Logon Status
Not logged on

Download
 GEMCO Type H & HM Installation, Dimensions and
 Service Manual:
   Microsoft Word® 97 format (3.6 MB)
   Adobe Acrobat® format (3.3 MB)
Get Viewer
Get Reader
INSTALLATION INSTRUCTIONS
Type A/H-HRC Panel

 
THESE INSTRUCTIONS COVER INSTALLATION OF THE FOLLOWING PANEL ASSEMBLIES:
Power Supply
380, 460 or 575V, 50/60 Hz AC
230VDC
Pressure Cluster
Air Hydraulic Ratio
8 x 1
5 x 1
8 x 1
5 x 1
No. of Pressure Clusters
1
2
J71020
J71022
J71021
J71023
J71024
J71026
J71025
J71027
 

A/H-HRC PANEL PIPING DIAGRAM
Mount the panel on a rigid vertical support, low enough for the 1/2" air line from the compressor to slope down to the air reservoir. This permits moisture to drain to the reservoir where it can be automatically ejected by the moisture valve.
 
Pipe and wire the panel into the system per applicable connection diagrams.
 
After the brake system is completely piped and wired, turn power ON. Check preset air pressures:
 
  1. Compressor supply pressure at gauge A must range from 65-80 psi. This pressure is controlled by 1PS N.C. pressure switch.

  2.  
  3. Emergency Brake pressure (ON when ESV solenoid valve is deenergized) is factory set at 40 psi. Check gauge B behind pressure
          regulator. This pressure may be reset in field.
          See "Pressure Adjustment Instructions"
          below.
  1. Abnormally low compressor supply pressure is signalled by 2PS N.O. pressure switch, which must close on 60 psi increasing pressure and open on 50 psi decreasing pressure.


SPECIAL BLEEDING AND PRESSURE ADJUSTMENT INSTRUCTIONS
FOR A/H-HRC SYSTEM
  1. Fill fluid reservoir/bleeder(s), pressure cluster(s) and control cylinder (and pilot circuit reservoir if used). Bleed A/H brake circuit by holding BPB bleeder pushbutton in and stroking pressure cluster(s) by repeatedly pushing BCV bleed control valve. Bleed the HRC hydraulic remote controlled circuit by opening the bleeder screw on the HRC valve and pumping the control cylinder until clear fluid escapes from the bleeder screw. Close bleeder screw. If HRC circuit includes coiled or looped hose, move trolley to cause straightest possible hose length when bleeding system.
  1. After brake system is bled and brakes are adjusted, operate brake system. Operation should be precise, without noticeable time delay. Check operation of emergency brake step by disconnecting power. The crane should come to a quick stop without abnormal hook swing. Adjust emergency pressure if necessary. Note: Application of emergency brake step initiates slow pressure bleed-down. Brake system is completely released after 1-2 hours.

AC WIRING DIAGRAM
TYPE A/H-HRC AIR/HYDRAULIC
PREWIRED CONTROL PANEL
DC WIRING DIAGRAM
TYPE A/H-HRC AIR/HYDRAULIC
PREWIRED CONTROL PANEL
Note: Standard AC Panels Are Designed For 460V operation. 1PS - N.C. Compressor Start-Stop Pressure Switch (80/65 PSI)
2PS - N.O. System Pressure Switch (60/50 PSI)
BPB - Bleeder Pushbutton