A/H-ARC PANEL PIPING DIAGRAM | ||||||||||||||||||||
![]() | ||||||||||||||||||||
|
Mount the panel on a rigid vertical support, low enough for the 1/2" air line from the compressor to slope down to the air reservoir. This permits moisture to drain into the reservoir where it can be automatically ejected by the moisture valve. Pipe and wire the panel into the system per applicable connection diagrams. When complete, turn power ON. Check preset air pressures. Compressor supply pressure at gauge A must range from 65-80 psi. This pressure is controlled by 1PS N.C. pressure switch. Low pressure alarm should |
sound below 50 psi. This is controlled by 2PS N.C. pressure switch. If reservoir pressure drops below 40 psi, the relay emergency valve applies system pressure. Special Bleeding Instructions for A/H Systems
|
ELECTRICAL CONTROL ASSEMBLY - WIRING DIAGRAM | |
![]() |
![]() |
![]() Pipe reservoir and delivery lines to the air relay valve on panel using 3/8" tubing provided. Install supply pressure gauge in cab. |
ALARM INSTALLATION 115VAC - J34778 230VDC - J24673 ![]() Mount alarm in cab. Make connections to panel per wiring diagram. |