Type A/H-ARC Four Brake, One Station System Piping TYPE A/H-ARC 4 BRAKE, 1 STATION SYSTEM PIPING DIAGRAM |
|
Mount both bleeders near panel, at same height, highest in the hydraulic system with static return lines to pressure clusters as short as possible. Hydraulic lines are 5/16" OD Copper, with 45° flare fitting, support tubing every three feet with rubber bushing and clamps. Avoid high loops in hydraulic lines. Locate compressor and air lines at an elevation that will permit condensed moisture to drain away from compressor into air supply tank. |
![]() |
![]() | ||||||||||||||||||
| ||||||||||||||||||
|
NOTE: AC Panels are prewired for 460V. High and Low voltage control leads must be reconnected for 230, 380 or 575V. CAUTION: Connect Motor Leads for Rotation as indicated by arrow on compressor. Do not start compressor until crankcase is filled with oil. Short circuit protection should be provided in accordance with National Electrical Code. |
![]() | ||||||||||||||||||
CAUTION: Connect Motor Leads for Rotation as indicated by arrow on compressor. Do not start compressor until crankcase is filled with oil. Short circuit protection should be provided in accordance with National Electrical Code. |
| Mount bleeders at the same height in hydraulic system, making return lines to pressure clusters and control cylinder as short as possible. All hydraulic lines are 5/16" copper brake line with flare fittings. Fasten every 3 feet with rubber bushing. Avoid high loops in hydraulic lines. | Locate compressor and air lines at an elevation that will permit condensed moisture to drain away from compressor into the air tank. Do not operate compressor unless 16 psi oil pressure is maintained in crankcase. |
![]() | |
![]() | ||||||||||||||||||||||||||||
|
NOTE: Panels are prewired for 460V. High and Low voltage control leads must be reconnected for 230, 380 or 575V. CAUTION: Connect Motor Leads for Rotation as indicated by arrow on compressor. Do not start compressor until crankcase is filled with oil. Short circuit protection should be provided in accordance with National Electrical Code. | |||||||||||||||||||||||||||
![]() | ||||||||||||||||||||||||||||
|
CAUTION: Connect Motor Leads for Rotation as indicated by arrow on compressor. Do not start compressor until crankcase is filled with oil. Short circuit protection should be provided in accordance with National Electrical Code. | |||||||||||||||||||||||||||
![]() |
![]() | |||||||||||||||||||||||||||||||||||||||
NOTE: Components Connected By Solid Lines Are Parts Supplied in MagneTek Brake System.
CAUTION: Connect Motor Leads for Correct Rotation as Indicated by Arrow on Compressor. DO NOT START COMPRESSOR UNTIL CRANKCASE IS FILLED WITH OIL. Connect MPR Contacts to Prevent Remote Operation Unless Sufficient Air Pressure is Available for Safe Braking. |
![]() | |||||||||||||||||||||||||||||||||||||||
Provision must be made to protect against short circuits in accordance with requirements of N.E.C. | ||||||||||||||||||||||||||||||||||||||||