The protection valve is a pilot operated check valve, used in
conjunction with a timer valve, to coordinate application of
parking brakes in type AHM-HRC and AHM-ERC system panels. With
normal minimum 65 psi pressure at control port B, service brake
ports E to D and parking brake release ports A to C are open.
When pressure at B drops to 40 psi, the valve closes port A to C
and exhausts C. When pressure at B drops to 30 psi, the valve
closes port E to D and exhausts D. |
![]() |
|
The valve must be replaced if it should fail to activate combination braking or
should a consistent air leak develop at the exhaust port. |

| 1 2 3 4 5 6 7 8 9 10 11 |
|
Valve Body Springtite Cap Screw (4 used) (10-24x7/8) Cap, Inlet Diaphragm Plunger Assy "O" Ring Spring Clip, Retainer Retainer, Spring Spring Valve Assy, Exhaust |
|
12 13 14 15 16 17 18 19 20 21 |
|
Springtite Cap Screw (2 used) (1/4-20x3/4) Cap, Applicaton Gasket Valve Assy, Inlet Spring Valve Guide "O" Ring "O" Ring Spring Valve and Seat Assy |