DESCRIPTION
Intrinsically Safe LDT - The 950IS is an intrinsically safe analog system. The system uses a remote transmitter mounted in a safe area wired
through intrinsically safe barriers to the LDT, which may be mounted in a hazardous area. The term 'Intrinsically Safe' pertains to a device's
inability to produce an electrical spark of enough significance to cause ignition. This system incorporates circuitry that is U.L. listed for
use in Class I, Groups C and D, Class II, Groups E, F and G, and Class III hazardous locations.
SPECIFICATION
Input Voltage/Current Draw - 24 VDC @ 85mA max.115 VAC 50/60 Hz @ 6 VA230 VAC 50/60 Hz @ 6 VA
Output - 0 to 10 VDC or 10 to 0 VDC4 to 20mA or 20 to 4mA
Linearity - .01"
Repeatability - +/- 0.01% of Full Stroke
Operating Temperature - Head Electronics, Guide Tube - 10o to 180o F (-23o to 82o C)-40o to 185oF (-40o to 85oC)
Operating Pressure - 3000 psi Operational, 8000 psi Spike
Span Length - 1" to 300"
Null Zone - 2"
Dead Band - 5
Connectors - 2 Pin 12m
Enclosure - IP65